The ELECTRONIC JAM DETECTING SENSOR (1), one of many on the outsert system, is part of “intelligent” self-teaching jam detection. Sensors throughout the system record the timing of sheet passage. If product does not arrive at a sensor point in the proper time, the operation preceding that point will shut down to prevent further jamming and minimize downtime.
sheets or a miss-feed. it activates the pneumatic cylinders that open the gate through which double sheets are ejected before they reach the folder. Production continues uninterrupted.
WATER SCORING (4), combined with rotary scoring, brings about accurate, tight folds.
FOLD-LENGTH MONITORS, one concealed above the exit rollers on Station I and one mounted beneath the exit rollers on Station II, measure product coming through and stop the machine when the folded length is incorrect.